The Knolle Pearce Lens Loop Cannula 23G is a specialized ophthalmic instrument designed for precise lens manipulation during delicate microsurgical procedures. Its lens loop configuration provides a focused working profile for controlled handling of lens material and related structures according to the surgeon’s technique.
Featuring a fine 23G profile, this cannula is suitable for ophthalmic procedures where accurate positioning and delicate instrument control are essential. The narrow working diameter allows the instrument to be handled within the confined surgical environment of the eye while supporting the precision required during cataract and anterior-segment procedures.
The Knolle Pearce pattern is designed for specialized ophthalmic use and can be incorporated into cataract surgery instrument sets. The lens loop portion may assist with engaging, positioning, or manipulating lens material during the appropriate stage of a procedure. The exact use should be determined by the surgeon according to the instrument configuration, surgical approach, and patient requirements.
The cannula’s fine profile can support controlled manipulation under surgical magnification. Ophthalmic microsurgical instruments must be positioned carefully to avoid unnecessary contact with surrounding structures, making precise instrument selection and handling particularly important. The Knolle Pearce Lens Loop Cannula provides a specialized option for professionals requiring a fine-gauge lens manipulation instrument.
Before each use, the instrument should be inspected carefully for deformation, damage, surface irregularities, or contamination. If the cannula incorporates a lumen, it should also be checked to ensure that the passage is clear and suitable for its intended function. Fine ophthalmic instruments require careful handling to maintain their shape and working characteristics.
For reusable configurations, the instrument should be thoroughly cleaned and processed according to the manufacturer’s validated instructions and the healthcare facility’s established reprocessing protocol. Particular attention should be given to any narrow lumen or difficult-to-access area during cleaning. Following cleaning, the instrument should be inspected before packaging and sterilization. Single-use configurations should be handled according to their labeling and should not be reused unless specifically authorized.
The Knolle Pearce Lens Loop Cannula 23G is a useful addition to professional ophthalmic surgical sets where controlled lens manipulation and fine microsurgical handling are required. Its specialized pattern, lens loop design, and 23G profile make it suitable for cataract and other delicate anterior-segment applications.
Key Features
- Knolle Pearce pattern
- Lens loop cannula design
- Fine 23G gauge
- Designed for ophthalmic microsurgery
- Supports controlled lens manipulation
- Suitable for cataract procedures
- Useful for anterior-segment applications
- Fine profile for precise surgical handling
- Designed for use under surgical magnification
- Suitable for specialized ophthalmic instrument sets
- Requires careful inspection and cleaning
- Reprocessing should follow validated manufacturer protocols
Product Specifications
| Specification | Details |
|---|---|
| Product Name | Knolle Pearce Lens Loop Cannula 23G |
| Instrument Type | Lens Loop Cannula |
| Pattern | Knolle Pearce |
| Gauge | 23G |
| Specialty | Ophthalmology |
| Primary Function | Lens Manipulation |
| Typical Application | Cataract & Anterior-Segment Surgery |
| Working Profile | Fine Gauge |
| Design | Lens Loop Cannula |
| Material | Surgical-grade instrument material |
| Reusable | Depends on product configuration |
| Sterilization | Follow manufacturer and facility-validated protocol |
FAQs
What is the Knolle Pearce Lens Loop Cannula 23G used for?
It is designed for controlled lens manipulation during cataract and other delicate ophthalmic microsurgical procedures.
What does 23G mean?
23G refers to the gauge of the cannula and indicates a fine working diameter suitable for delicate ophthalmic applications.
Can this instrument be used during cataract surgery?
Yes, the Knolle Pearce Lens Loop Cannula is designed for specialized lens manipulation applications associated with cataract and anterior-segment procedures.
What is the purpose of the lens loop?
The lens loop is designed to assist with controlled engagement, positioning, or manipulation of lens material according to the surgeon’s technique.
How should this cannula be cleaned?
A reusable version should be carefully cleaned and inspected, with attention to any narrow or difficult-to-access areas, before sterilization according to validated protocols.
Is the Knolle Pearce Lens Loop Cannula reusable?
Reusability depends on the specific product configuration and manufacturer labeling. Always follow the manufacturer’s instructions for use.
Why is a 23G lens loop cannula useful?
The fine 23G profile provides a compact working diameter that supports precise handling within the delicate surgical environment of the eye.