Tympanoplasty Knife 6 ½” 7mm Curved Blade
Tympanoplasty Knife 6 ½” 7mm Curved Blade Original price was: $100.00.Current price is: $65.00.
Back to products
Incudostapedial Joint Knife 5 × 1.5mm Blade, Angled 2
Incudostapedial Joint Knife 5 × 1.5mm Blade, Angled 2 Original price was: $100.00.Current price is: $60.00.

Incudostapedial Joint Knife 75mm Diameter Blade, Angled

The Incudostapedial Joint Knife is a specialized otologic surgical instrument designed for controlled incision and delicate manipulation around the incudostapedial joint. Its angled working configuration supports precise access within the confined middle-ear surgical field.

Original price was: $100.00.Current price is: $65.00.

Whatapp Inquiry
14 People watching this product now!

Payment Methods:

Description

The Incudostapedial Joint Knife 75mm Diameter Blade, Angled is a specialized otologic surgical instrument designed for precise incision and controlled manipulation during procedures involving the delicate structures of the middle ear. Its angled configuration allows the working end to approach the surgical area from a controlled direction, making it suitable for specialized ENT and otologic instrument sets.

The instrument is designed around the requirements of delicate middle-ear surgery, where accurate positioning, controlled movement, and appropriate visualization are important. The angled working end can help the clinician access areas that may be difficult to approach with a straight instrument, particularly when working around the incudostapedial joint and adjacent anatomical structures.

The stated 75mm blade dimension should be verified against the manufacturer’s catalog specification, as instrument listings can sometimes use millimeter measurements to describe overall dimensions, shaft characteristics, or working components. For product identification and ordering, the exact specification supplied with the instrument should be used to confirm compatibility with the intended surgical application.

As an incudostapedial joint knife, this instrument is intended for professional otologic use rather than general-purpose surgical cutting. Its focused design supports controlled incision-related tasks and localized manipulation where a dedicated ear surgery knife is required. The angled profile can assist with maintaining a suitable approach while minimizing unnecessary repositioning of the instrument.

The instrument can be incorporated into ENT, otology, and middle-ear surgical trays. Its specific clinical application should always follow the manufacturer’s intended use and the surgeon’s established technique. Because procedures involving the middle ear require careful handling of delicate anatomical structures, appropriate visualization, surgical training, and controlled instrument movement are essential.

The Incudostapedial Joint Knife is typically manufactured from surgical-grade stainless steel when supplied as a reusable surgical instrument. This type of material provides the strength, durability, and corrosion resistance expected from professional surgical instrumentation. A smooth surgical finish also supports appropriate cleaning and decontamination procedures when the instrument is designed for repeated use.

Regular inspection is important for maintaining the instrument’s working condition. The angled blade should be checked for deformation, damage, corrosion, or changes to its intended profile before each procedure. Proper cleaning, drying, sterilization, and storage should be performed according to the manufacturer’s validated instructions and the healthcare facility’s approved instrument-processing protocol.

For hospitals, ENT departments, otology specialists, ambulatory surgical centers, and professional medical instrument suppliers, this angled incudostapedial joint knife provides a dedicated option for precision ear surgery. Its specialized design makes it suitable for surgical trays requiring instruments capable of controlled access and manipulation within the middle-ear field.

Key Features

  • Specialized incudostapedial joint knife
  • Angled working configuration
  • Designed for precision otologic procedures
  • Suitable for controlled incision and manipulation
  • Supports access within confined middle-ear anatomy
  • Designed for localized surgical work
  • Suitable for ENT and otology instrument sets
  • Typically manufactured from surgical-grade stainless steel
  • Durable construction for professional surgical environments
  • Smooth surface supports appropriate cleaning and maintenance
  • Reusable when supplied as a reusable instrument
  • 75mm diameter specification as listed

Product Specifications

Specification Details
Product Type Incudostapedial Joint Knife
Specialty ENT / Otology
Blade Specification 75mm diameter, as listed
Blade Configuration Angled
Primary Function Controlled incision and manipulation
Surgical Area Middle Ear / Incudostapedial Joint
Working Profile Angled surgical blade
Material Typically surgical-grade stainless steel
Finish Smooth surgical finish
Reusable Yes, when supplied as reusable
Sterilization Follow validated manufacturer/facility protocol
Application Specialized otologic procedures

FAQs

1. What is the Incudostapedial Joint Knife used for?

It is a specialized otologic instrument designed for controlled incision and manipulation around the incudostapedial joint and nearby middle-ear structures.

2. Is this knife suitable for ENT procedures?

Yes. It is designed for specialized ENT and otologic surgical applications.

3. What is the blade configuration?

The instrument features an angled blade configuration for controlled access within the surgical field.

4. What does the 75mm diameter specification refer to?

The product is listed with a 75mm diameter specification. The exact dimensional reference should be confirmed against the manufacturer’s technical specification before ordering.

5. What material is the instrument typically made from?

It is typically manufactured from surgical-grade stainless steel when supplied as a reusable surgical instrument.

6. Can this instrument be sterilized?

If supplied as a reusable instrument, it should be cleaned and sterilized according to the manufacturer’s validated instructions and the healthcare facility’s approved processing protocol.

7. What should be inspected before use?

The angled working end should be checked for deformation, damage, corrosion, or changes to its intended working profile before use.