The Locking Medial Proximal Tibial Plates (4.5 / 5.0mm Left & Right) with Screws are advanced orthopedic fixation implants used for the treatment of fractures involving the upper (proximal) tibia near the knee joint. The anatomically pre-contoured design ensures precise fit along the medial aspect of the tibia, providing strong support for load-bearing and restoration of proper joint alignment.
These plates are commonly used in complex proximal tibial fractures, including intra-articular, split-depression, comminuted, and osteoporotic fracture patterns. The medial positioning allows effective stabilization of the tibial plateau while maintaining anatomical reduction of the knee joint.
The locking compression plate (LCP) system allows 4.5mm and 5.0mm locking screws to securely engage within the plate, forming a fixed-angle construct that enhances stability, reduces screw loosening, and maintains fracture reduction even in weak or osteoporotic bone conditions.
The plate is available in left and right anatomical configurations to match patient-specific tibial anatomy, ensuring accurate alignment and improved surgical outcomes. Multiple hole options provide flexibility based on fracture severity and fixation requirements.
Manufactured from premium surgical-grade stainless steel or titanium (depending on configuration), the implant offers excellent strength, corrosion resistance, and long-term biocompatibility. Precision-engineered screw holes ensure accurate placement and reliable intraoperative performance.
This system is widely used in orthopedic trauma surgery and veterinary orthopedic procedures for proximal tibial fracture management.
The implant is fully sterilizable and supplied in professional surgical packaging for safe handling and efficient operating room workflow.
Specifications Table
| Feature | Details |
|---|---|
| Product Name | Locking Medial Proximal Tibial Plates |
| Application | Proximal tibia fracture fixation |
| Plate Type | Anatomical locking compression plate |
| Screw Sizes | 4.5mm / 5.0mm locking screws |
| Side Options | Left & Right |
| Material | Stainless Steel / Titanium |
| Usage | Orthopedic & veterinary surgery |
| Function | Bone stabilization & fixation |
| Sterilization | Fully sterilizable |
FAQs
Q1: What is this plate used for?
It is used for fixation of proximal tibia (knee region) fractures.
Q2: Why are left and right plates required?
They are anatomically contoured for each side of the tibia.
Q3: What screw sizes are used?
4.5mm and 5.0mm locking screws.
Q4: What materials are used?
Stainless steel or titanium.
Q5: Is it used in veterinary surgery?
Yes, it is commonly used in veterinary orthopedic procedures.