Denhardt Mouth Gag with Silicone Inserts 5 1/8
Denhardt Mouth Gag with Silicone Inserts 5 1/8 Original price was: $100.00.Current price is: $60.00.
Back to products
THRUBITE Blakesley Punch Forceps Size 1 3 x 8mm Straight
THRUBITE Blakesley Punch Forceps Size 1 3 x 8mm Straight Original price was: $110.00.Current price is: $80.00.

Stammberger Punch Circular Straight Cutting 18cm 3.5mm Diameter

The Stammberger Punch Circular Straight Cutting 18cm with a 3.5mm diameter is designed for precise tissue removal and controlled surgical access in ENT procedures. Its straight profile and compact circular cutting end provide accurate handling in confined operative areas.

Original price was: $200.00.Current price is: $180.00.

Whatapp Inquiry
19 People watching this product now!

Payment Methods:

Description

The Stammberger Punch Circular Straight Cutting 18cm 3.5mm Diameter is a specialized ENT surgical instrument designed for controlled tissue removal and operative access during nasal and sinus procedures. Its straight shaft configuration provides a direct working path, while the compact 3.5mm circular cutting diameter supports precise manipulation in areas where controlled tissue removal is required.

With an overall length of 18 cm, the instrument provides practical reach for procedures involving the nasal cavity and paranasal sinus region. The relatively narrow 3.5mm working diameter allows the surgeon to work within restricted anatomical spaces while maintaining visibility and control. Its design makes it suitable for selected functional endoscopic sinus surgery (FESS) and other rhinologic procedures where precision is important.

The circular cutting mechanism is intended to engage and remove targeted tissue in a controlled manner. Compared with broader cutting instruments, the 3.5mm working end can provide more localized tissue removal, which may be beneficial when working close to delicate anatomical structures. Proper visualization and careful instrument positioning remain essential during clinical use.

The straight configuration of the Stammberger punch provides a straightforward approach to the operative site. It can be particularly useful when a direct instrument path is preferred during nasal and sinus surgery. The 18cm length balances working reach with instrument control, allowing the surgeon to manipulate the punch while maintaining an appropriate distance from the operative field.

This type of ENT punch is commonly associated with rhinology and sinus surgery applications. It may be used for selected procedures involving removal of soft tissue, mucosal tissue, or other obstructive material according to the surgeon’s technique and the specific clinical indication. The instrument should always be selected according to the anatomical location, procedure, and required cutting profile.

When supplied as a reusable surgical instrument, the Stammberger punch is commonly manufactured from durable surgical-grade stainless steel or comparable medical instrument material. A smooth surface and precisely formed working components support reliable handling and facilitate appropriate cleaning. The cutting mechanism should be inspected regularly to ensure that it remains properly aligned and free from damage.

After use, the instrument should be cleaned and decontaminated according to the healthcare facility’s validated instrument-processing procedures. Particular attention should be given to the working mechanism and internal areas where biological material may accumulate. Sterilization should be performed using a validated method compatible with the instrument and in accordance with applicable manufacturer instructions.

The Stammberger Punch Circular Straight Cutting 18cm 3.5mm Diameter is a practical choice for ENT and rhinology professionals seeking a precise straight punch for controlled tissue removal. Its 18cm length, 3.5mm circular cutting diameter, and direct shaft design provide a useful combination of access, control, and precision for appropriate surgical applications.

Key Features

  • Stammberger-style circular straight cutting punch
  • Overall length: 18 cm
  • Cutting diameter: 3.5 mm
  • Straight shaft for direct surgical access
  • Compact working end for controlled tissue removal
  • Designed for ENT and rhinology applications
  • Suitable for selected sinus and nasal procedures
  • Useful for controlled work in confined anatomical areas
  • Provides precise instrument positioning and manipulation
  • Durable construction for professional surgical use
  • Reusable when supplied as a reusable instrument
  • Requires appropriate cleaning, inspection, and sterilization

Product Specifications

Specification Details
Product Name Stammberger Punch Circular Straight Cutting
Instrument Type ENT Surgical Punch
Working Style Circular Cutting
Shaft Straight
Overall Length 18 cm
Cutting Diameter 3.5 mm
Primary Specialty ENT / Rhinology
Applications Nasal and Sinus Procedures
Construction Surgical-Grade Metal*
Reusable Yes, when supplied as reusable
Sterilization Validated surgical sterilization protocol

*Material specifications should be confirmed against the supplied instrument and manufacturer documentation.

FAQs

What is a Stammberger Punch used for?

A Stammberger punch is used for controlled tissue removal and surgical access during selected ENT, nasal, and sinus procedures.

What is the diameter of this Stammberger Punch?

This model has a 3.5 mm circular cutting diameter.

What is the length of this instrument?

The Stammberger Punch has an overall length of 18 cm.

Is this punch suitable for FESS procedures?

It can be used in selected functional endoscopic sinus surgery procedures where its straight configuration and 3.5mm cutting profile are appropriate for the intended surgical technique.

What does the straight design provide?

The straight shaft provides a direct working path and can help with controlled positioning during nasal and sinus procedures.

Is the Stammberger Punch reusable?

When supplied as a reusable instrument, it can be cleaned, inspected, and sterilized according to validated healthcare-facility procedures and manufacturer instructions.

How should this ENT punch be sterilized?

It should be thoroughly cleaned and processed using a validated sterilization method compatible with the instrument’s construction. Manufacturer reprocessing instructions should always be followed.

Why choose a 3.5mm cutting diameter?

The 3.5mm working diameter provides a relatively compact cutting profile for controlled tissue removal in confined nasal and sinus operative areas.