Gimbel Forward Irrigating Cannula 30g
Gimbel Forward Irrigating Cannula 30g Original price was: $100.00.Current price is: $60.00.
Back to products
Simcoe DB I A Unit 23g
Simcoe DB I A Unit 23g Original price was: $100.00.Current price is: $60.00.

McIntyre Binkhorst I A Straight 26g

The McIntyre Binkhorst I/A Straight 26G Cannula is designed for controlled irrigation and aspiration during delicate ophthalmic procedures. Its straight configuration and fine 26G profile support precise fluid management in microsurgical applications.

Original price was: $100.00.Current price is: $60.00.

Whatapp Inquiry
18 People watching this product now!

Payment Methods:

Description

The McIntyre Binkhorst I A Straight 26g is a specialized ophthalmic microsurgical instrument designed for controlled irrigation and aspiration during procedures requiring precise intraocular fluid management. The McIntyre Binkhorst pattern is commonly associated with ophthalmic irrigation and aspiration applications, making this cannula a useful component of cataract and other delicate anterior-segment surgical procedures.

Featuring a straight configuration and fine 26G profile, this cannula is designed for controlled access and fluid handling in confined surgical fields. The straight shaft provides a direct working orientation, while the small gauge supports delicate manipulation where a fine cannula profile is preferred. Its configuration allows the surgeon to manage irrigation and aspiration functions with appropriate compatible ophthalmic fluid-management equipment.

The McIntyre Binkhorst I/A Straight 26G Cannula can be incorporated into ophthalmic instrument sets used for cataract surgery, anterior-segment procedures, and other microsurgical applications requiring controlled aspiration or irrigation. It may be particularly useful where precise removal of fluid, residual material, or surgical debris is required while maintaining careful control of the operative field.

The instrument is designed with microsurgical handling in mind. Its compact working profile allows it to be used alongside other delicate ophthalmic instruments without unnecessarily obstructing the surgical field. The straight design also provides a predictable approach for surgeons who prefer direct cannula positioning during fluid-management steps.

Manufacturing from suitable surgical-grade metal provides the rigidity and durability expected from a reusable ophthalmic instrument, depending on the specific product configuration. A properly finished surface helps support routine cleaning, inspection, and maintenance while reducing areas where contaminants may accumulate. The cannula should always be inspected before use to ensure that the working opening and shaft are free from blockage, damage, or deformation.

After use, the McIntyre Binkhorst I/A Straight 26G Cannula should be processed according to the healthcare facility’s validated cleaning and sterilization protocol and the manufacturer’s instructions. Particular attention should be given to the cannula lumen because small-gauge ophthalmic instruments can require careful flushing and inspection to ensure unobstructed fluid passage.

For ophthalmic surgical departments, ambulatory surgery centers, specialty clinics, and professional instrument sets, the McIntyre Binkhorst I/A Straight 26G Cannula provides a specialized solution for controlled irrigation and aspiration. Its recognizable pattern, straight configuration, and fine 26G profile make it a practical choice for delicate ophthalmic microsurgical fluid-management applications.

Key Features

  • McIntyre Binkhorst pattern
  • Straight shaft configuration
  • Fine 26G cannula profile
  • Designed for irrigation and aspiration
  • Suitable for ophthalmic microsurgery
  • Supports controlled intraocular fluid management
  • Useful in cataract and anterior-segment procedures
  • Compact design for delicate surgical fields
  • Suitable for use with compatible I/A systems
  • Durable surgical instrument construction
  • Reusable depending on product configuration
  • Requires validated cleaning and sterilization procedures

Product Specifications

Specification Details
Product Name McIntyre Binkhorst I/A Straight 26G
Instrument Type Ophthalmic Irrigation & Aspiration Cannula
Pattern McIntyre Binkhorst
Configuration Straight
Gauge 26G
Function Irrigation and Aspiration
Specialty Ophthalmology
Application Cataract and anterior-segment microsurgery
Working Profile Fine
Material Typically surgical-grade metal
Reusable Depending on product configuration
Sterilization Follow validated facility protocol and manufacturer instructions

FAQs

1. What is the McIntyre Binkhorst I/A Straight 26G Cannula used for?

It is designed for controlled irrigation and aspiration during delicate ophthalmic microsurgical procedures.

2. What does 26G mean?

26G refers to the cannula gauge, indicating a fine-diameter profile suitable for delicate ophthalmic applications.

3. What does I/A mean in ophthalmic surgery?

I/A means irrigation and aspiration, referring to controlled delivery and removal of fluid during microsurgical procedures.

4. What is the advantage of the straight configuration?

The straight configuration provides a direct working orientation and can support predictable positioning during fluid-management steps.

5. Is this cannula suitable for cataract surgery?

It may be used as part of compatible ophthalmic irrigation and aspiration systems during cataract and related anterior-segment procedures.

6. Can the McIntyre Binkhorst cannula be reused?

Reusable use depends on the specific product configuration and manufacturer instructions. Reusable instruments must be properly cleaned, inspected, and sterilized.

7. How should a 26G I/A cannula be sterilized?

It should be cleaned and sterilized according to the healthcare facility’s validated protocol and the manufacturer’s instructions, with careful attention to the small internal lumen.