14″ Tendon Stripper, Autoclavable Handle, 4 mm
14″ Tendon Stripper, Autoclavable Handle, 4 mm Original price was: $100.00.Current price is: $60.00.
Back to products
11 inch tendon stripper with a 4 mm inner diameter and autoclavable handle
11 inch tendon stripper with a 4 mm inner diameter and autoclavable handle Original price was: $100.00.Current price is: $60.00.

24” Tendon Stripper Autoclavable Handle 3mm

The 24″ Tendon Stripper with Autoclavable Handle and 3 mm working size is designed for controlled tendon harvesting and graft preparation. Its extended length provides increased reach while supporting precise instrument handling during orthopedic and reconstructive procedures.

Original price was: $110.00.Current price is: $80.00.

Whatapp Inquiry
14 People watching this product now!

Payment Methods:

Description

The 24” Tendon Stripper Autoclavable Handle 3mm is a specialized surgical instrument designed for tendon harvesting, separation, and preparation. Its extended 24-inch length provides substantial working reach, making it suitable for surgical techniques where access along the length of a tendon requires an elongated instrument.

Tendon strippers are commonly used during procedures involving tendon graft harvesting. The 3 mm working size provides a defined internal working dimension that can be selected according to the tendon size and requirements of the surgical technique. Appropriate instrument sizing is important for achieving controlled advancement and efficient preparation of tendon tissue.

The extended 24-inch profile allows the instrument to reach along longer tendon structures while keeping the handle positioned away from the immediate operative area. This design can provide practical access and controlled manipulation during tendon harvesting. The long shaft is particularly useful when the surgical approach requires additional reach without unnecessarily repositioning the surgeon’s hands.

The autoclavable handle is designed for reusable surgical environments where validated cleaning and sterilization procedures are followed. A practical handle configuration allows the instrument to be advanced and manipulated with controlled movements. The handle and working portion should be inspected before each use to ensure proper condition and cleanliness.

This tendon stripper may be used in orthopedic surgery, sports medicine, reconstructive surgery, and tendon graft preparation. Tendon grafts can be required for various reconstructive procedures, including ligament reconstruction and other techniques involving harvested tendon tissue. The specific use, approach, and instrument size should always be determined by the qualified surgical professional according to the procedure.

The 3 mm working size is a key selection specification. Smaller working dimensions may be appropriate for particular tendon harvesting requirements or techniques where a more compact internal diameter is preferred. The correct size should be selected based on the tendon being harvested and the surgeon’s established technique.

Reusable tendon harvesting instruments are commonly manufactured from durable surgical-instrument materials designed to tolerate repeated cleaning and sterilization. Smooth working surfaces and a properly finished shaft can support routine inspection and cleaning. Exact material specifications may vary according to the manufacturer and supplied configuration.

Following each procedure, the tendon stripper should be cleaned promptly according to the healthcare facility’s validated reprocessing protocol. Particular attention should be given to the working end, shaft, handle, and any areas where biological material may collect. When supplied as an autoclavable reusable instrument, steam sterilization should be performed according to the manufacturer’s validated instructions and applicable facility procedures.

Proper handling, cleaning, inspection, and sterilization can help maintain the instrument’s performance and service life. The 24″ Tendon Stripper with 3 mm working size provides extended reach, controlled handling, and an autoclavable handle for professional tendon harvesting and preparation applications.

Key Features

  • 24-inch overall length
  • 3 mm working size
  • Autoclavable handle
  • Designed for controlled tendon harvesting
  • Suitable for tendon graft preparation
  • Extended length for increased working reach
  • Supports controlled advancement along tendon tissue
  • Suitable for orthopedic surgical procedures
  • Useful for sports medicine applications
  • Suitable for reconstructive procedures
  • Designed for reusable surgical workflows
  • Compatible with validated cleaning and sterilization protocols

Product Specifications

Specification Details
Product Name Tendon Stripper
Instrument Type Tendon Harvesting Instrument
Overall Length 24 inches
Working Size 3 mm
Handle Autoclavable
Primary Application Tendon Harvesting & Preparation
Surgical Specialty Orthopedic Surgery
Additional Applications Sports Medicine & Reconstructive Surgery
Use Tendon Graft Preparation
Reusable Yes, when supplied as reusable
Sterilization Autoclave according to validated instructions
Intended Users Surgeons and Trained Healthcare Professionals

FAQs

1. What is a 24-inch tendon stripper used for?

A 24-inch tendon stripper is designed to assist with controlled tendon harvesting and preparation during orthopedic, sports medicine, reconstructive, and tendon graft procedures.

2. What does the 3 mm working size mean?

The 3 mm working size identifies the internal working dimension of the tendon stripper and helps clinicians select an appropriate instrument for the intended harvesting technique.

3. Why is this tendon stripper 24 inches long?

The 24-inch length provides extended reach along longer tendon structures and can be useful when the surgical technique requires an elongated working instrument.

4. Is the handle autoclavable?

Yes. This model is specified with an autoclavable handle for compatible reusable surgical workflows.

5. Can this instrument be used for tendon graft harvesting?

Yes. Tendon strippers are commonly used to assist with harvesting and preparing tendon tissue for suitable grafting procedures.

6. Is the 24″ tendon stripper reusable?

It is intended for reusable surgical use when supplied as a reusable instrument and should be properly cleaned, inspected, and sterilized between procedures.

7. How should the tendon stripper be sterilized?

The instrument should be cleaned and sterilized according to the manufacturer’s validated instructions and the healthcare facility’s established reprocessing protocol.

8. What specialties use tendon strippers?

Tendon strippers may be used in orthopedic surgery, sports medicine, reconstructive surgery, and procedures involving tendon graft harvesting