Stammberger Punch Circular Straight Cutting 18cm 4.5mm Diameter
Stammberger Punch Circular Straight Cutting 18cm 4.5mm Diameter Original price was: $200.00.Current price is: $180.00.
Back to products
THRUBITE Blakesley Punch Size 0 2.5 x 7mm Up 45°
THRUBITE Blakesley Punch Size 0 2.5 x 7mm Up 45° Original price was: $120.00.Current price is: $90.00.

THRUBITE Blakesley Punch Forceps Pediatric 1.5 x 6mm Up 45° Sz 00

The Pediatric ThruBite Blakesley Punch Forceps Size 00 features a compact 1.5 x 6mm working end with a 45° upward angle for controlled tissue manipulation. Its pediatric configuration is designed for precise access during selected ENT, nasal, and sinus procedures.

Original price was: $215.00.Current price is: $120.00.

Whatapp Inquiry
20 People watching this product now!

Payment Methods:

Description

The THRUBITE Blakesley Punch Forceps Pediatric 1.5 x 6mm Up 45° Sz 00 is a specialized ENT surgical instrument designed for controlled tissue grasping, cutting, and removal in pediatric otolaryngology procedures. Its compact 1.5 x 6mm working end and 45° upward angle provide a precise configuration for accessing smaller or confined anatomical areas where a pediatric-sized instrument may be preferred.

Blakesley punch forceps are commonly used in ENT, rhinology, nasal, and sinus surgery for the controlled removal of soft tissue, mucosal tissue, polyps, and other targeted structures. The Size 00 pediatric configuration provides a smaller working profile, supporting careful tissue engagement where a larger punch may be less suitable. Instrument selection should always be based on the patient’s anatomy, surgical approach, and clinician preference.

The 45° upward angle allows the working end to approach tissue from an elevated direction while helping keep the handle and shaft positioned outside the immediate operative area. This angled configuration can be useful when direct access with a straight instrument is limited. The compact 1.5 x 6mm working dimensions further support controlled manipulation within restricted surgical fields.

The ThruBite mechanism is designed to provide controlled movement of the working jaws through operation of the handle. This allows the surgeon to engage targeted tissue and perform measured biting movements during appropriate procedures. The smaller jaw profile can support selective tissue removal while maintaining the precision required for delicate pediatric ENT applications.

Constructed from surgical-grade stainless steel, this Blakesley Punch Forceps is designed for durability, corrosion resistance, and professional reusable use when appropriately maintained. Stainless steel construction supports routine cleaning, disinfection, and sterilization procedures applicable to reusable surgical instruments. Smooth finished surfaces also facilitate visual inspection and cleaning after use.

The instrument’s ergonomic operating design helps provide controlled handling during repeated jaw movements. A responsive mechanism and properly maintained working components can support consistent instrument performance. Regular inspection of the jaws, shaft, handle, and moving mechanism is recommended to identify wear, damage, or restricted movement before clinical use.

This Pediatric ThruBite Blakesley Punch Forceps Size 00 may be incorporated into pediatric ENT, otolaryngology, rhinology, nasal surgery, and sinus surgery instrument sets. Its small working end and upward 45° configuration make it suitable for selected procedures where precise access and controlled tissue manipulation are required.

As with other reusable surgical instruments, proper cleaning and sterilization are essential. Following a procedure, the forceps should be cleaned promptly according to a validated instrument-processing protocol to remove blood, tissue, and other contaminants. It should then be thoroughly rinsed, dried, inspected, and sterilized using a validated method compatible with the instrument and the healthcare facility’s requirements.

The combination of pediatric Size 00, 1.5 x 6mm working dimensions, and a 45° upward angle makes this ThruBite Blakesley Punch Forceps a practical option for specialized ENT applications requiring a compact and controlled working profile. Its durable construction and dedicated pediatric configuration make it a useful addition to professional pediatric otolaryngology instrument collections.

Key Features

  • Pediatric ThruBite Blakesley Punch Forceps
  • Size 00 compact configuration
  • 1.5 x 6mm working end
  • 45° upward-angled working end
  • Designed for controlled tissue manipulation and removal
  • Suitable for selected pediatric ENT procedures
  • Compact profile for smaller anatomical areas
  • Useful for nasal, sinus, and rhinology applications
  • Surgical-grade stainless steel construction
  • Ergonomic design for controlled operation
  • Durable reusable construction with appropriate processing
  • Smooth surfaces support cleaning and routine maintenance

Product Specifications

Specification Details
Product Name ThruBite Blakesley Punch Forceps
Configuration Pediatric
Size 00
Working End 1.5 x 6mm
Jaw Direction Up
Angle 45°
Specialty Pediatric ENT / Otolaryngology
Applications Nasal, Sinus & Rhinology Procedures
Function Tissue Grasping, Cutting & Removal
Material Surgical-Grade Stainless Steel
Reusable Yes, with appropriate processing
Sterilization Validated surgical instrument sterilization protocols

FAQs

What is a Pediatric ThruBite Blakesley Punch Forceps used for?

It is an ENT surgical instrument designed for controlled tissue manipulation and removal during selected pediatric nasal, sinus, and otolaryngology procedures.

What size is this pediatric Blakesley Punch?

This model is Size 00 and features a 1.5 x 6mm working end.

What does the 45° up configuration mean?

The 45° up configuration indicates that the working end is angled upward by approximately 45 degrees, helping provide access to tissue from an elevated approach.

Why use a Size 00 Blakesley Punch?

The Size 00 configuration provides a compact working profile that may be useful when working within smaller or more confined anatomical areas during appropriate pediatric ENT procedures.

What are the jaw dimensions?

The working end measures 1.5 x 6mm, providing a compact configuration for controlled tissue engagement.

Is this Blakesley Punch suitable for pediatric ENT surgery?

It is designed for pediatric ENT applications, including selected nasal and sinus procedures where its compact size and angled working end are appropriate.

What material is this instrument made from?

The forceps are manufactured from surgical-grade stainless steel for durability, corrosion resistance, and suitability for reusable surgical instrument processing.

How should the pediatric Blakesley Punch be sterilized?

The instrument should be cleaned and sterilized according to validated healthcare-facility procedures and applicable manufacturer instructions for reusable surgical instruments.