Bowel Grasper 35 cm, With Ratchet, Rota Clear
Bowel Grasper 35 cm, With Ratchet, Rota Clear Original price was: $210.00.Current price is: $120.00.
Back to products
Prestige Type Grasper 36 cm, Non Rotating, SA with Slide Lock
Prestige Type Grasper 36 cm, Non Rotating, SA with Slide Lock Original price was: $250.00.Current price is: $150.00.

Biopsy Punch 35 cm, Flushable, Monopolar

The Biopsy Punch 35 cm is a specialized surgical instrument designed for controlled tissue sampling and excision in minimally invasive and endoscopic procedures. Its flushable shaft, 35 cm working length, and monopolar configuration provide practical access and compatibility with electrosurgical techniques when appropriate.

Original price was: $210.00.Current price is: $115.00.

Whatapp Inquiry
20 People watching this product now!

Payment Methods:

Description

The Biopsy Punch 35 cm Flushable Monopolar is a specialized minimally invasive surgical instrument designed for obtaining tissue samples and performing controlled tissue excision during appropriate endoscopic and surgical procedures. Its extended 35 cm working length provides useful access through an endoscopic or minimally invasive approach while allowing the surgeon to maintain control of the instrument from outside the operative field.

The punch-style working end is designed to remove a defined portion of tissue for biopsy or other indicated surgical applications. A biopsy punch allows controlled sampling from the target area and can be particularly useful when a precise tissue specimen is required for pathological examination. The specific jaw or punch configuration should be selected according to the tissue type, anatomical location, and requirements of the procedure.

This model features a flushable shaft, which is designed to allow appropriate flushing and cleaning of the internal pathway during instrument reprocessing. Flushable instrumentation can help facilitate more effective cleaning of internal channels where applicable, supporting thorough removal of biological material and procedural debris. Proper flushing should always be performed according to the instrument manufacturer’s validated cleaning instructions.

The 35 cm length offers extended reach for minimally invasive access while maintaining practical handling characteristics. This working length can be useful in procedures where the target site is located at a greater distance from the external access point. The shaft provides a controlled pathway to the operative field while the handle allows the user to manipulate the distal working mechanism.

The instrument is also specified as monopolar, indicating that it is designed for use with an appropriate monopolar electrosurgical system when the complete instrument configuration and surgical setup support such use. Monopolar electrosurgical instruments require compatible equipment and proper operating technique. Appropriate electrosurgical safety protocols, including correct connection, insulation inspection, and system compatibility, should be followed before clinical use.

The biopsy punch is typically manufactured using durable surgical materials intended for professional clinical environments. A robust construction supports repeated handling and, where the instrument is designated reusable, repeated processing in accordance with the manufacturer’s instructions. The working jaws or punch mechanism should maintain accurate movement and alignment to support controlled tissue sampling.

For reusable instruments, proper cleaning and sterilization are essential. Immediately after use, the instrument should be processed according to the validated reprocessing procedure applicable to the specific model. The flushable channel should be appropriately irrigated or flushed, while the working end, shaft, handle, and mechanical components should be thoroughly cleaned. Following cleaning, the instrument should be inspected for structural damage, insulation integrity, smooth mechanical operation, and proper punch function before sterilization and reuse.

The Biopsy Punch 35 cm Flushable Monopolar combines extended reach, tissue-sampling functionality, internal flushability, and monopolar electrosurgical capability in one specialized instrument. It is a practical option for professional surgical and endoscopic instrument sets where controlled biopsy or tissue excision is required.

Key Features

  • 35 cm working length for extended minimally invasive access
  • Biopsy punch design for controlled tissue sampling
  • Suitable for tissue biopsy and indicated excision procedures
  • Flushable shaft facilitates internal cleaning and reprocessing
  • Monopolar configuration for compatible electrosurgical applications
  • Designed for controlled manipulation of the distal working end
  • Suitable for endoscopic and minimally invasive surgical procedures
  • Ergonomic handle for controlled instrument operation
  • Durable construction for professional surgical environments
  • Designed for reliable mechanical performance
  • Reusable when supplied as a reusable instrument and properly maintained
  • Requires appropriate cleaning, inspection, and sterilization between uses

Product Specifications

Specification Details
Product Name Biopsy Punch 35 cm
Instrument Type Biopsy Punch
Length 35 cm
Shaft Flushable
Electrosurgical Configuration Monopolar
Primary Function Tissue Biopsy and Excision
Application Endoscopic / Minimally Invasive Surgery
Working Mechanism Punch-Type Tissue Sampling
Handle Surgical Instrument Handle
Material Surgical-Grade Materials*
Reusable Yes, subject to manufacturer specifications
Sterilization According to validated manufacturer protocol*
Intended Users Qualified Surgical Professionals

*Exact material and sterilization compatibility should be verified against the specific instrument manufacturer’s specifications.

FAQs

1. What is a 35 cm biopsy punch used for?

A 35 cm biopsy punch is used for controlled tissue sampling or excision during appropriate endoscopic and minimally invasive surgical procedures.

2. What does flushable mean on a biopsy punch?

Flushable indicates that the instrument incorporates a pathway designed to permit appropriate flushing during cleaning and reprocessing, helping remove biological material from internal areas where applicable.

3. What does monopolar mean on this biopsy punch?

Monopolar means the instrument is configured for use with a compatible monopolar electrosurgical system when indicated. Appropriate electrosurgical equipment and safety protocols must be used.

4. Why is the instrument 35 cm long?

The 35 cm working length provides extended reach through minimally invasive or endoscopic access points, allowing the working end to reach deeper operative sites.

5. Can this biopsy punch be used for tissue sampling?

Yes. Its punch mechanism is designed for controlled removal of tissue specimens for biopsy and other clinically indicated applications.

6. Is the Biopsy Punch 35 cm suitable for endoscopic procedures?

It is designed for appropriate minimally invasive and endoscopic applications where its size, working mechanism, and electrosurgical configuration are compatible with the procedure and equipment.

7. How should the flushable biopsy punch be cleaned?

The instrument should be cleaned using the manufacturer’s validated reprocessing instructions. Where applicable, the internal flushable pathway should be thoroughly flushed as part of the cleaning process.

8. Is this biopsy punch reusable?

If supplied as a reusable surgical instrument, it may be reused after appropriate cleaning, inspection, sterilization, and maintenance in accordance with the manufacturer’s instructions.

9. What should be inspected before using a monopolar biopsy punch?

The working mechanism, shaft, insulation, electrical connection points, handle, and flushable pathway should be inspected according to the applicable manufacturer and facility protocols before use.